Electrodes
Parts & Solutions
Optional Units
Application Description Code Remarks
Neutralization titration
pH combined electrode (general purpose)
GST-5741C One of standard accessories of AUT-701
pH combined electrode (precision measurement)
ELP-035
pH combined electrode (double junction) ELP-062
Junction is replaceable. Effective against KCl inner solution outow problem
Redox titration
ORP combined electrode (general purpose) PS-5111C
ORP combined electrode (double junction) ELM-016
Junction is replaceable. Effective against KCl inner solution outow problem
Salinity titration Silver combined electrode (general purpose) ELX-006 Junction is replaceable
Non-aqueous titration
Glass electrode (general purpose) HGS-2005
Optional electrode adapter (0JD00001) and electrode holder
(S-HLD-S) will be required.
Reference electrode (double junction) HS-305DS
Photometric titration
Immersion electrode OPE-21A Attached with photometric titration unit
Polarization titration
Twin platinum electrode HPD-303 Attached with polarization titration unit
Electric conductivity titration
Electric conductivity cell CT-57101B Attached with electric conductivity titration unit
Parts for titrator
Description Code Remarks
Magnetic stirrer ST-7
Standard accessories of AUT-701
For dual system separate order would be required
Electrode stand with stopper 6948810K
Electrode holder 0IB00001
Electrode attachment (G) 0IB00004
Electrode attachment (J) 0IB00005
Electrode attachment (N) 0IB00008
Electrode adapter 0JD00001
Required for using glass electrodes and reference electrodes
Electrode holder S-HLD-S
Electrode relaying lead wire (1m) 0GB00001
Electrode relaying lead wire (3m) 0GB00002
Micro-titration kit 7075600K
Content : Adaptor, Titration nozzle, Titration cell (50 pcs.), O-ring P-5 (2 pcs.),
O-ring P12 (2 pcs.) , Stirring bar (2 pcs.)
Turntable connection cable (2m) 7075670K For TTT-510 connection
AST connection cable (2m) 7075710K For AST-3210 connection
RS-232 cable (2m) 0GC00002 For PC connection (D-sub9p for PC connection)
Reference electrode inner solution, 100mL (saturated KCl solution)
143F237 For reference electrode (HS-305DS and others)
Reference electrode outer solution RE-2, 100mL 143F238 For electrode for salinity titration
Printer chart paper (5 rolls/pack) PAP-HCS For internal printer, one of standard accessories of AUT-701
Parts for burette
Description Code Remarks
Unit plate (for 1mL to 20mL syringe) 7075610K
Unit plate (for 50mL syringe) 7075620K
20mL brown syringe AUT-045P
50mL brown syringe P000010
10mL brown syringe AUT-046P
5mL brown syringe AUT-047P
1mL brown syringe AUT-048P
Degassing nozzle (for 1mL to 20mL syringe) P000070
Degassing nozzle (for 50mL syringe) P000071
Titration nozzle (for micro titration) AST-P008
Reagent bottle with tube joint 7075630K 1,000mL translucent brown plastic bottle
Carbon dioxide adsorbent with tube 7075640K One of standard accessories of ABT-7
Teflon tube, black, 2m (for 5mL to 20mL syringe) AUT-022P For 5mL to 50mL syringe
Teflon tube, black, 2m (for 1mL syringe) AUT-024P Only for 1mL syringe
Photometric Titration Unit
FUT-7010
(Immersion electrode OPE-21A attached)
Used to detect the color
variation of indicator and
used for quantitative
analysis of metallization
like plating solution.
The adaptor is built into
 the titrator and the amp.
 unit is standalone.
Amp. unit dimension : Approx. W102 X H153 X D119 mm
Standard interference filter : 530 nm, 630 nm
Polarization Titration Unit
FUT-7030
Twin platinum electrode HDP-303 attached
Used for iodide value or diazo
titration.
This unit is built into the titrator.
Measuring method : constant-current voltage method,
constant-voltage current method
Detecting electrode : twin platinum electrode (HDP-303)
Applied voltage : 0
+/
-
1,000 mV (settable at optimum voltage)
Applied current : 0
+/
-
1,000 μA (settable at optimum voltage)
Electric Conductivity Titration Unit
FUT-7040
(Conductivity cell CT-57101B attached)
Can be used for electric conductivity measurement.
This unit is built into the titrator.
Measuring method : AC two electrode
method
Measuring range : 0
200.0S/m
(depends on cell)
Manual ranging
when titration set
by titrator.
Auto ranging when electric
conductivity measurement
Temperature : 0
100.0℃
Potentiometric Titration Unit
FUT-7050
(Electrode is option)
This unit is built into the titrator.
mV : 0 +/
-
2,000.0 mV
Temperature : 0
100.0℃
Adapter
Amp. unit
Two wave length
auto switching available